How is the Harvia Cilindro Half installed?
The Harvia Cilindro Half stands on the floor on adjustable legs, beside a side wall or in a corner, and is fixed to the wall with the supplied wall-mounting device and two fixing kits; after the final hookup the electrician screws it to the floor with at least two screws or bolts. It can also be set into a bench cut-out with a Harvia embedding flange (sold separately), and Harvia's flange instructions allow the bench closer to the heater than the distances below when a flange is used. Harvia's Cilindro manual says only a licensed electrician may connect it, permanently wired through seal-tight conduit, and a sauna room takes only one electric heater. The control's power unit goes outside the sauna room, and the WX248 temperature sensor that ships with the heater mounts near the ceiling. Your licensed electrician sizes the breaker and wire from the manual that ships with the heater and your local code. Harvia's installation manual, under Documents, gives the exact sensor, vent and wiring positions.
Harvia Cilindro Half safety distances
Keep at least these distances between the Harvia Cilindro Half and walls, benches and anything that can burn. Harvia's room guidance also keeps the sauna ceiling no higher than 7 ft 6 in (2,300 mm).
Harvia Cilindro Half, every output (Harvia Cilindro Half manual Y05-0769, §3.2–3.3 and Figures 3 and 5)
| Heater side to a side wall or bench side (A) |
1.2" (30 mm) |
| Heater front to the heater fence or bench (B) |
4" (100 mm) |
| Heater fence |
Required by Harvia: softwood, fixed to the wall, at least 4" (100 mm) in front of the heater and at least 32" high, with its top at least 1" below the top of the heater; built on site, not in the box |
| Floor to the underside of the heater |
At least 2.8" (70 mm) |
| Floor under and near the heater |
Heat-resistant; Harvia advises dark grout and stone floor coverings there |
Harvia Cilindro Half ceiling distance and room height by output (Harvia Cilindro Half manual Y05-0769, Table 2 and Figure 5)
|
6 kW |
8 kW |
9 kW |
10.5 kW |
| Top of the heater to the ceiling (C) |
35" (890 mm) |
35" (890 mm) |
35" (890 mm) |
32.5" (830 mm) |
| Sauna room height, minimum |
75" (1,900 mm) |
75" (1,900 mm) |
75" (1,900 mm) |
78" (1,980 mm) |
Does the sauna room need ventilation?
Yes. Harvia's Cilindro manual calls for an adjustable supply vent near the floor close to the heater and an exhaust vent, on the opposite wall where possible, for about five air changes an hour; the manual gives their positions, and local code may ask for more.