How is the Harvia Virta Combi 9 kW installed?
The Harvia Virta Combi 9 kW stands on the sauna floor on adjustable legs, which level it. Harvia's manual asks for a heat-resistant floor covering where the heater stands, because hot pieces of stone can damage floor coverings. Harvia allows one electric heater per sauna room unless several heaters share one control unit. The heater is hardwired: Harvia's manual allows no plug or receptacle in the sauna room, and only an authorized, licensed electrician may connect it. The control's power unit goes on a wall outside the sauna room, in a dry place above 32°F (0°C), and the WX248 temperature sensor that comes with the heater mounts above it. Your licensed electrician sizes the breaker and wire from the manual that ships with the heater and your local code. Harvia's installation manual, under Documents, gives the exact sensor, wiring and vent positions.
Harvia Virta Combi 9 kW safety distances
Keep at least these distances between the Harvia Virta Combi 9 kW and walls, benches and anything that can burn.
Harvia Virta Combi 9 kW minimum distances (Harvia Virta Combi manual 26092023/Y05-0898)
| Heater to side walls, back wall and benches |
2" (50 mm) |
| Top of the heater to the ceiling |
42" (1,060 mm) |
| Heater fence (required, not in the box) |
Harvia's manual calls a softwood heater fence necessary for safety: at least 2" (50 mm) from the heater on every side and at least 28" (711 mm) high, with its top at least 1" below the top of the heater and never above the rock line |
| Sauna room height |
At least 75" (1,900 mm); ceiling no higher than 7 ft 6 in (2,300 mm) |
Does the sauna room need ventilation?
Yes. Harvia's Virta Combi manual calls for adjustable vents that change the air five times an hour: a supply vent low down beside the heater and an exhaust vent on the opposite wall. The manual gives their positions.
Does the Harvia Virta Combi 9 kW need a water line?
Only for automatic filling. The Harvia Virta Combi 9 kW's steamer can fill its 1.3 gal (5 L) tank automatically from a cold-water supply line with a shut-off valve and a vacuum breaker, at 22–58 psi (150–400 kPa), and Harvia recommends a floor drain. Without a water line, the tank is filled by hand, after a jumper in the heater is removed.