HUUM HIVE Flow 9.8kW Wood-Burning Sauna Heater Package
HUUM HIVE Flow 9.8 kW wood-burning stove, 330 lb of stones, Protective Bed L and a HUUM chimney kit in one package, for 282–635 cu ft sauna rooms
In stock
Estimated delivery
7–12 days after you order
In stock
Estimated delivery
7–12 days after you order
In stock
Estimated delivery
7–12 days after you order
In stock
Estimated delivery
7–12 days after you order
- HUUM: 75% of the firewood's heat goes into the sauna, not up the chimney
- Stove, stones, floor bedding and chimney kit matched in one order
- 330 lb of HUUM stones included
- Description
- What's Included
- Specifications
- Installation
- Documents
- Warranty
What is the HUUM HIVE Flow 9.8 kW wood-burning package?
The HUUM HIVE Flow 9.8 kW package combines four parts: the HUUM HIVE Flow wood-burning sauna stove, 10 boxes (330 lb) of HUUM Stones 24, the HUUM Protective Bed L that goes under the stove, and one HUUM chimney kit, chosen by option. It is sized for sauna rooms of 282–635 cu ft, burns firewood only and needs no electricity. The package price is the sum of the four parts; ordering them together means the stones, bedding and chimney kit are already matched to the stove.
The HUUM HIVE Flow stove stands on the floor, holds 330 lb of 2–4" stones (10 boxes of 33 lb) in a metal grate around the stove body, and connects to the chimney at the top or the back.
HUUM says 75% of the heat from the firewood goes directly into the sauna rather than escaping up the chimney, and that the large stone mass keeps giving steam for more than 30 minutes after the fire is out. In the Engineering Test Institute's emissions report, the HIVE Flow and HIVE Flow LS reached 74.9% gross efficiency, with particulate emissions of 17 mg/m³. HUUM says its design reduces fire risk, allowing a snug installation. A large glass door shows the fire, and the furnace design is patent pending.
Which chimney kit should I choose?
Choose the kit by where the chimney leaves the sauna. HUUM lists all four for the HIVE Flow; only the backside kit uses the stove's rear connection.
| Connects at | Route out of the sauna | |
|---|---|---|
| Thru-Wall | Top | Rises from the top of the stove, turns 90° through the wall and runs up the outside of the building |
| Thru-Flat or Curved Ceiling | Top | Goes straight up through a flat or curved (barrel) ceiling and roof |
| Thru-Angled Ceiling | Top | Goes up through the ceiling and out through a roof pitched 0–20° |
| Thru-Wall Backside Connection | Back | Leaves the back of the stove straight through the wall, then runs up the outside of the building |
What's included in the HUUM HIVE Flow 9.8 kW package?
HUUM HIVE Flow stove
- The sauna stove
- Metal stone grate
- Ash grate
- Ash drawer
- Cleaning hatches (2)
- Metal fixing plates (2), used for a back chimney connection
- Splints
- Heat-resistant glove
- Installation and operation manual
HUUM Stones 24
- 10 boxes × 33 lb = 330 lb of rounded 2–4" (5–10 cm) HUUM Stones 24
HUUM Protective Bed L
- HUUM Protective Bed L, the size HUUM makes for the HIVE Flow (HUUM says its S and L bedding does not suit LS models)
- Height adjustable 2.2–2.9" (56–75 mm) on adjustable feet
- Carries up to 661 lb (300 kg)
- Also sold on its own: Protective Bed L
HUUM chimney kit
- One kit, by the option you choose: HUUM Thru-Wall Chimney Kit, HUUM Thru-Flat or Curved Ceiling Chimney Kit, HUUM Thru-Angled Ceiling Chimney Kit, HUUM Thru-Wall Backside Connection Chimney Kit
- Each kit's parts list is on the kit's own product page
What you still need
- A certified installation expert to connect the stove to the chimney
- On a combustible floor, a sheet-metal plate in front of the stove door: at least 4" past each side of the door opening and 15 3/4" forward (HUUM's manual)
- Optional: the HUUM stone cage (Cage HSTV), offered with this package
HUUM HIVE Flow stove specifications
| HUUM model and part number | HIVE Flow, H1015012 |
|---|---|
| Heat output | 9.8 kW nominal |
| Sauna room volume | 282–635 cu ft (8–18 m³); add 3.3 cu ft per sq ft of uninsulated brick, tile or glass wall |
| Dimensions | 34.8" H × 20.7" W × 23.1" D (884 × 526 × 586 mm); the door handle adds 1.7" (44 mm) to the depth |
| Weight | 148 lb (67 kg) without stones |
| Stones | Included: 10 boxes × 33 lb = 330 lb (150 kg) of 2–4" HUUM Stones 24 |
| Floor protection under the stove | Included: the HUUM Protective Bed L; HUUM requires a non-combustible base on a wood or other combustible floor |
| Floor plate in front of the door | Required on a combustible floor, at least 4" past each side of the door opening and 15 3/4" forward; not included |
| Chimney | Included: one HUUM chimney kit, by the option you choose; a certified installer connects it |
| Chimney connection on the stove | Top or back; 4.5" (114 mm) chimney leg; the chimney must be temperature class T450 with at least 16 sq in (10,400 mm²) cross-section |
| Mounting collar | Not needed: the HIVE Flow stands wholly inside the sauna; only the LS models pass through a wall |
| Stone cage | Optional, not included; the HUUM Cage HSTV is offered as an add-on with this package |
| Electrical connection | None needed; wood-fired, no controller |
| Fuel | Firewood only, hardwood or softwood, 10–15% moisture |
| Firewood length | 12" recommended, 16" maximum |
| Flue gas temperature | 642°F average and 725°F maximum at nominal output |
| Efficiency and emissions | 74.9% gross efficiency; CO 346 mg/m³ and particulates 17 mg/m³ at 13% O₂ (emissions report, Engineering Test Institute, Brno) |
| Emission standards | Certified to EN 15821 under the EU Construction Products Regulation (certificate CPR-B-00659-24); meets Germany's 1. BImSchV Stage 2, per the emissions report of the Engineering Test Institute, Brno |
| Sauna room height | 75" (1,900 mm) minimum; 79–91" recommended |
| Made in | Estonia; furnace design patent pending |
| Warranty | 3 years private use, 1 year commercial use (HUUM); the door glass, ash grate and stones are excluded |

All four HIVE Flow stoves, and a package for each, are in the HUUM HIVE Flow collection; HUUM's HIVE Wood stoves are with them in the HUUM wood-burning sauna stove collection.
How is the HUUM HIVE Flow 9.8 kW package installed?
The HIVE Flow stands on a non-combustible floor strong enough to carry it and its 330 lb of stones; HUUM names a concrete floor at least 2" (50 mm) thick as suitable. On wood or another combustible floor, HUUM's manual makes a non-combustible base mandatory, such as the HUUM Protective Bed L included in the package, with a ventilation gap of at least 1 3/16" (30 mm) under it, and it is also recommended over underfloor heating pipes. A sheet-metal plate must cover the combustible floor in front of the stove, reaching at least 4" (100 mm) past each side of the door opening and 15 3/4" (400 mm) forward, with the edge nearest the stove bent up so coals cannot slide under it.
HUUM HIVE Flow safety distances
Keep at least these distances from the HIVE Flow to walls, benches and anything that can burn. The letters match HUUM's drawing.

| A: sides and back | 6" (150 mm) |
|---|---|
| B: in front of the door | 20" (500 mm) |
| C: total side-to-side span (A + stove + A) | 33" (826 mm) |
| Above the stove | 40" (1,000 mm) |
| To a non-combustible wall | 2" (50 mm) |
A non-combustible protective screen cuts the side distances by 50% (single screen) or up to 75% (double screen), and the distance to the ceiling by 25% (single screen only); the distance is still measured to the combustible surface. HUUM asks you to check local safety rules before reducing any distance. The sauna room must be at least 75" tall; HUUM recommends 79–91", with 44–51" from the top bench to the ceiling.
Connecting the HIVE Flow to a chimney
Only a certified installation expert may connect the HIVE Flow to the chimney. HUUM's manual calls for a chimney of temperature class T450 with a cross-section of at least 16 sq in (10,400 mm²), joined to the stove's 4.5" (114 mm) chimney leg at the top or the back. For a back connection the bolted chimney leg and its cover plate swap places, and two ribs of the stone grate are cut and fixed with the two metal fixing plates in the box. Seal the joints with heat-resistant rope or stone wool. Because the flue gas stays below 752°F (400°C), HUUM allows the stove to share an existing flue that already serves a fireplace, if your local authority and fire department agree.
| Connects at | Route out of the sauna | |
|---|---|---|
| Thru-Wall | Top | Rises from the top of the stove, turns 90° through the wall and runs up the outside of the building |
| Thru-Flat or Curved Ceiling | Top | Goes straight up through a flat or curved (barrel) ceiling and roof |
| Thru-Angled Ceiling | Top | Goes up through the ceiling and out through a roof pitched 0–20° |
| Thru-Wall Backside Connection | Back | Leaves the back of the stove straight through the wall, then runs up the outside of the building |
HUUM's manual asks for fresh supply air directed as close to the HIVE Flow as possible, and warns that forced (mechanical) ventilation can starve the fire of combustion air, so check the ventilation design before the first sauna. It also advises checking local fire safety rules before installing a wood-burning stove.
Before the first fire: HUUM's outdoor burn-in
HUUM's manual requires the HIVE Flow to be fired outdoors at least once before it is installed, because the protective paint on the stove body gives off unpleasant fumes while it cures. Remove the stone grate, lay no stones, fit the ash grate, ash drawer and cleaning hatches, and burn one or two loads of firewood in a sheltered, well-ventilated spot with the door slightly open, never closed, until no smoke or steam comes off the surface. Do not throw water on the stove. A length of flue pipe on the chimney leg improves the draft.
Lighting the HIVE Flow and adding wood
Burn firewood only, hardwood or softwood at 10–15% moisture, in logs of about 12" (30 cm), no longer than 16" (40 cm), weighing 0.8–1.5 lb each. Lay thin wood at the bottom, the thickest in the middle and kindling on top, then light it from the top. Keep the ash drawer open (its limiter allows 1/8") for no more than 15 minutes, then close it for the rest of the heating. Add wood only once the previous load has burned down to glowing coals, filling the firebox to no more than two thirds of its height. HUUM's maximum loads for the HIVE Flow are 11 lb (5 kg) to start, then 5 lb (2.2 kg) and 4 lb (1.8 kg), and no more than 9 lb (4 kg) per hour. If the stove surface glows red it is overheating: close the air valve under the door at once.
Stones, steam and yearly care
Wash the 330 lb of stones, check that the cleaning hatches are in place, then lay the stones evenly, layer by layer, level with the top of the grate, without forcing any between the grate and the stove body. Make steam only once the stones are fully hot: about 1/3 cup (80 ml) of water at a time, never salt or chlorinated water. HUUM says the stones keep giving steam for more than 30 minutes after the fire is out. Have a chimney sweep clean the chimney, the flue connections and the stove's own flues at least once a year, check the stones yearly, and expect to renew them about every two years. Check the door seal each time you clean the glass, and never heat the stove with cracked glass.
HUUM warranty periods
HUUM's limited warranty (Limited Warranty Terms and Conditions, US, v2) covers new HUUM products bought from HUUM or its authorized dealers, such as Topture, against defects in materials and workmanship. The period starts on the date the end user buys the product.
| HUUM product | Private use | Commercial use |
|---|---|---|
| Electric sauna heaters | 3 years | 1 year |
| Wood-burning sauna stoves | 3 years | 1 year |
| Control units (UKU) | 3 years | 1 year |
| Spare parts | 1 year | 1 year |
HUUM counts as commercial use a business using the product commercially, a private owner using it commercially, or a private owner using it for more than 1,500 hours in 12 months.
What the warranty does not cover
- Heating elements of electric heaters
- HUUM accessories, such as rails, reflectors, flanges, protective bedding and chimney parts
- Door glass and ash grate of wood-burning stoves
- Sauna stones
- All controller sensors
- Damage from a heater that is the wrong size for the room, from unsuitable stones, or from installation, use or maintenance that does not follow HUUM's manuals
What keeps the warranty in effect
- Inspect the product when it arrives and report any visible damage within 7 days, with photos, before installing it.
- Install it following HUUM's manual and local building, electrical and fire codes. An electric product must be connected by a licensed electrician, with proof of the installation.
- Report a defect within 30 days of finding it. For products bought from Topture, report it to Topture, which passes the claim to HUUM and helps with troubleshooting.