How is the HUUM DROP installed?
The DROP hangs on the supplied mounting plate and is secured with a safety bolt. With the HUUM Flange D it can instead sit partly inside the bench or floor, with at least 14 3/4" (375 mm) of the heater above the bench.
HUUM's DROP manual says the electrical connection must be made by a licensed electrician, on its own circuit, with a heat-resistant power cable (no PVC insulation) and crimped wire ends. Your electrician sizes the breaker and wire from the manual that ships with the heater and your local code.
HUUM DROP safety distances
Keep at least these distances from the HUUM DROP to walls, benches and anything that can burn. The letters match the drawing.

HUUM DROP minimum safety distances (DROP 2.0 manual v8, Table 1)
|
4.5 kW |
6 kW |
7.5 kW |
9 kW |
| A |
3 15/16" (100 mm) |
4 23/32" (120 mm) |
5 1/2" (140 mm) |
5 29/32" (150 mm) |
| B |
23 7/32" (590 mm) |
24 13/16" (630 mm) |
26 3/8" (670 mm) |
27 5/32" (690 mm) |
| C |
17 1/8" (435 mm) |
17 29/32" (455 mm) |
18 11/16" (475 mm) |
19 3/32" (485 mm) |
| D |
6 11/16" (170 mm) |
7 15/32" (190 mm) |
8 9/32" (210 mm) |
8 21/32" (220 mm) |
-
A: minimum distance from the heater to a side wall, and to a bench or other obstruction beside or in front of it
-
B: minimum width from a side wall to a bench or obstruction on the far side of the heater
-
C: minimum distance from the wall behind the heater to a bench or obstruction in front of it
-
D: minimum distance from an adjoining corner wall to the edge of the mounting plate
-
E: at least 12 7/32" (310 mm) from the floor to the bottom of the mounting plate
- At least 47 1/4" (1,200 mm) from the top of the heater to the ceiling, and 3 15/16" (100 mm) from its bottom to the floor
HUUM requires a sauna room at least 75" tall (79–91" recommended) with 44–51" from the top bench to the ceiling.
Stacking and caring for the stones
Stack the stones by hand so they cover the elements completely; a sparsely filled basket is a fire hazard, and visible elements void the safety distances. HUUM recommends checking the stones after 100 hours of use (or yearly), replacing cracked stones after 200 hours and replacing all of them after 400 hours.
HUUM DROP videos