How is the Harvia Vega Compact 1900 installed?
The Harvia Vega Compact 1900 hangs on a wall-mounting rack that is screwed into a board or other solid wood behind the wall panel, not into the panel alone, with the bottom of the heater 3.1–7.8" above the floor. A sauna room takes only one electric heater, and the floor under it should be heat-resistant. Harvia's manual says only a licensed electrician may connect the heater: it is hardwired, with no plug in the sauna room. Your licensed electrician sizes the breaker and wire from the manual that ships with the heater and your local code. Harvia's installation manual, under Documents, gives the exact rack and wiring details.
Harvia Vega Compact 1900 safety distances
Keep at least these distances between the Harvia Vega Compact 1900 and walls, benches and anything that can burn. They are the same for the 1900 and the 3500.
Harvia Vega Compact minimum safety distances (Harvia Vega Compact manual Y05-0583, Figures 4 and 5)
| Heater side to a side wall |
At least 0.8" |
| Heater front to a bench |
At least 3.1" |
| A bench or fence beside or above the heater, horizontally |
At least 0.4" |
| Top of the heater to the underside of a bench above it |
At least 0.8" |
| Top of the heater to the ceiling |
At least 46" |
| Bottom of the heater to the floor |
3.1–7.8" |
| Heater fence |
Required: Harvia's manual says a fence is necessary for safety. Softwood, attached to the wall, no higher than the top of the heater; not included |
| Sauna room height |
At least 75" (1,900 mm); Harvia's room guidance keeps the ceiling no higher than 7' 6" |
Does the sauna room need ventilation?
Yes. Harvia's manual for the Vega Compact calls for adjustable vents that change the air five times an hour: a lower vent close to the heater and an upper vent on the opposite wall. The manual gives their positions.